Lovato Electric comprehensive line of contactors can be divided in to three basic
configurations. Each of these have unique features but all are designed
for long life and have finger-safe protection. Lovato Electric facilities, where
these contactors are manufactured, work under ISO 9001 quality conditions,
per IQNet certification since 1992 and constantly maintained by passing yearly quality
assurance audits. The design and manufacture of the contactors and accessories have taken
into consideration the most demanding international standards requirements.

BG series
6A/3HP - 12A/7.5HP

• Highly conductive auxiliary contacts with four contact points
• AC and DC versions of same size
• Quick connect - snap on accessory mounting
• Distinct contact status indication
• Up to four auxiliary contacts can be mounted
• Mechanical interlock only 5mm deep
• Low DC consumption interface version
• Positively guided contacts (mechanically-linked per IEC)


BF series
9A/5HP - 110A/75HP

• 4 different contactor frame sizes up to 75HP
• Anti-shock magnetic core design
• Straight through wiring
• Captive raised terminal screws to reduce wiring time
• Wide coil operating range
• Coil removable without disconnecting power wiring
• Oversized main contacts
• Easy contact inspection and replacement
• Special main pole configurations
• Specific version for power factor correction systems
• Positively guided contacts (mechanically-linked per IEC)


B series
110A/75HP - 630A/500HP

• 3 frame sizes offering 11 different contactors
• Coil operate indifferently on AC or DC supply voltage
• Coil with low in-rush and holding
• Coil removable without disconnecting power wiring
• Red indicator when contactor is energized
• Unique right-angle magnet design - limits contact bounce
• Safety feature prevents contactor to be energized without arc chute in place and locked
• Convertible auxiliary contact block (2NO + 1NC or 1NO + 2NC), maximum of 4 blocks per contactor for a total of 12 contacts
• Contactor terminals furnished with bolt, washer and nut
• Simple horizontal or vertical interlock
• Positively guided contacts (mechanically-linked per IEC)


Maximum Horsepower RatingsUL AMP RatingMaximum CurrentBase mounted auxiliary contactsPart Number
PDF File
Single PhaseThree phaseInductive AC3Resistive AC1
120v240v200v240v480v600v
[HP][HP][HP][HP][HP][HP][A][A][A]NONCAC Coil
1/311 1/2233166161011BG0610A*
1/311 1/2233166160111BG0601A*
1/21 1/22355209201011BG0910A*
1/21 1/22355209200111BG0901A*
1/21 1/2337 1/2102012201011BG1210A*
1/21 1/2337 1/2102012200111BG1201A*
3/423357 1/22592510BF0910A*
3/423357 1/22592501BF0901A*
12557 1/21028122810BF1210A*
12557 1/21028122801BF1201A*
1355101532183210BF1810A*
1355101532183201BF1801A*
237 1/27 1/2151532253210BF2510A*
237 1/27 1/2151532253201BF2501A*
257 1/27 1/2152045264500BF2600A*
37 1/21010202555325600BF3200A*
37 1/21015303055385600BF3800A*
510101530409050900011BF5000*
--20255060110651100011BF6500*
--25306075125801250011BF8000*
--30306075125951250011BF9500*
--3030751001251101250011BF11000*



Copyright © 2009 Kent Industries Incorporated